1387 item(s)
No. | Picture | Model | Description | Brand | Action |
---|---|---|---|---|---|
1001. | ![]() | Q250 | Gas flowmeter, Flowrate: 20-400m3/h, Size: DN100 mm, Connection: Flanged to PN16, Body material: GGG-40 ductile iron, Dimension: 150mm long flange to flange | Elster | ![]() |
1002. | ![]() | Q270A1024 | Subbase for RA890 | Honeywell | ![]() |
1003. | ![]() | Q298B1065 | Damper linkage for adapting 90° modutrol motor to gas valve | Honeywell | ![]() |
1004. | ![]() | Q345A1305 | Igniter Sensor, include 1/4" cc inlet fitting and mounting adaptor | Honeywell | ![]() |
1005. | ![]() | Q347A1004 | Spark igniter, 2 1/32 in (52mm) electrode length | Honeywell | ![]() |
1006. | ![]() | Q354A1018 | Flame detector | Honeywell | ![]() |
1007. | ![]() | Q455C1052 | Valve linkage for Modutrol IV motor | Yamatake | ![]() |
1008. | ![]() | Q5001D1018 | Valve linkage for Modutrol IV motor | Honeywell | ![]() |
1009. | ![]() | Q520A1121 | Subbase for R4140 | Honeywell | ![]() |
1010. | ![]() | Q520A1139 | Subbase for R4150P | Yamatake | ![]() |
1011. | ![]() | Q520D1003 | Subbase for R4150N, R4150P | Yamatake | ![]() |
1012. | ![]() | Q605F1018 | Damper linkage, ½" diameter shaft | Honeywell | ![]() |
1013. | ![]() | Q607C1009 | Auxiliary switch, 1 switch | Honeywell | ![]() |
1014. | ![]() | Q624A1014 | Solid state ignition transformer, P:120Vac, S:15,000V peak | Honeywell | ![]() |
1015. | Q641A1000 | Subbase for R4341 & R4344 | Honeywell | ![]() | |
1016. | ![]() | Q643B1005 | Subbase for R4343 | Honeywell | ![]() |
1017. | ![]() | Q7230A1005 | Interface module Modutrol IV motor | Honeywell | ![]() |
1018. | ![]() | Q7800A1005 | 22-Terminal universal wiring subbase, panel mount | Honeywell | ![]() |
1019. | ![]() | Q7800B1003 | 22-Terminal universal wiring subbase, burner or wall mount | Honeywell | ![]() |
1020. | ![]() | QM20TB-H | Power transistor | Mitsubishi | ![]() |
1021. | ![]() | QRA50M | UV flame detector | Landis & Gyr | ![]() |
1022. | ![]() | QRA53.C17 | Photo cell, 110Vac | Landis & Gyr | ![]() |
1023. | ![]() | R1061012 | Ignition lead (specify length) rated at 350°F | Honeywell | ![]() |
1024. | ![]() | R1298020 | Flame rod lead (specify length) rated at 400°F | Honeywell | ![]() |
1025. | ![]() | R4140G1114 | Automatic programming control, 240Vac, pre-purge:70 sec, FEP:10,30 or 60 sec, postpurge:25 sec | Honeywell | ![]() |
1026. | ![]() | R4140L1014 | Automatic programming control, 120Vac, pre-purge:60sec, FEP:10 or 15 sec, postpurge:15 sec | Honeywell | ![]() |
1027. | ![]() | R4140L1105 | Automatic programming control, 120Vac, pre-purge:60sec, FEP:10 or 15 sec, postpurge:15 sec, early spark termination:5 sec | Honeywell | ![]() |
1028. | ![]() | R4140L1147 | Automatic programming control, 120Vac, pre-purge:60sec, FEP:10,15 or 30 sec, postpurge:15 sec, early spark termination:5 sec | Honeywell | ![]() |
1029. | ![]() | R4140L1154 | Automatic programming control, 240Vac, pre-purge:60 sec, FEP:5 or 10 sec, post-purge:15 sec | Honeywell | ![]() |
1030. | ![]() | R4140L1170 | Automatic programming control, 240Vac, pre-purge:60 sec, FEP:5 or 10 sec, post-purge:15 sec | Honeywell | ![]() |
1031. | ![]() | R4150P1046X15 | Flame safeguard programming control, 100vac, 55s pre-purge, 20s post purge, 30s safety switch | Yamatake | ![]() |
1032. | ![]() | R4150P1053X15 | Flame safeguard programming control, 200Vac, 55s pre-purge, 20s post-purge, 30s safety switch | Yamatake | ![]() |
1033. | ![]() | R4332B100-1 | Maximum safety flame safeguard, multiburner module, power & shutter voltage:100Vac | Yamatake | ![]() |
1034. | ![]() | R4341B1088 | Burner programmer, 220Vac, 38s pre-purge, 12s post-purge | Honeywell | ![]() |
1035. | ![]() | R4341B1096 | Burner programmer, 240Vac, 38s pre-purge, 12s post-purge | Honeywell | ![]() |
1036. | ![]() | R4341B1104 | Burner programmer, 115Vac, 38s pre-purge, 12s post-purge | Honeywell | ![]() |
1037. | ![]() | R4341B1120 | Burner programmer, 220Vac, 38s pre-purge, 12s post-purge | Honeywell | ![]() |
1038. | ![]() | R4341B1153 | Burner programmer, 115Vac, 38s pre-purge, 12s post-purge | Honeywell | ![]() |
1039. | ![]() | R4341C1086 | Burner programmer, 220Vac, 70s pre-purge, 9s post-purge | Honeywell | ![]() |
1040. | ![]() | R4343D1017 | Flame switch, 220 Vac, response time < 1 sec, use with flame rod or C7012G | Honeywell | ![]() |
1041. | ![]() | R4343E1006 | Flame switch, 110Vac, response time < 1 sec, use with C7027, C7035 & C7044 | Honeywell | ![]() |
1042. | ![]() | R4343E1014 | Flame switch, 220 Vac, response time < 1 sec, use with C7027, C7035 & C7044 | Honeywell | ![]() |
1043. | ![]() | R4348A1000 | Flame switch, 110/120/220/240Vac selectable | Honeywell | ![]() |
1044. | ![]() | R4348A1018 | Flame switch with flame current jack, 110/120/220/240Vac selectable | Honeywell | ![]() |
1045. | ![]() | R4348A1026 | Flame switch with flame current LED indicator, 110/120/220/240Vac selectable | Honeywell | ![]() |
1046. | ![]() | R4348B1008 | Flame switch 3-pole line voltage load relay, 110/120/220/240Vac selectable | Honeywell | ![]() |
1047. | ![]() | R4348B1057 | Flame switch with flame current LED indicator, 3-pole line voltage load relay, 110/120/220/240Vac selectable | Honeywell | ![]() |
1048. | ![]() | R4715B1003-1 | Protectorelay, 100Vac, prepurge:15 sec, post-ignition:11 sec, lockout:23 sec, FFRT:1.5 ±0.5 sec, 150 MCal/h | Yamatake | ![]() |
1049. | ![]() | R4715B1011-1 | Protectorelay, 200Vac, prepurge:15 sec, post-ignition:11 sec, lockout:23 sec, FFRT:1.5 ±0.5 sec, 150 MCal/h | Yamatake | ![]() |
1050. | ![]() | R4715C1019 | Protectorelay, 200Vac, prepurge:15 sec, post-ignition:1.2 sec, lockout:23 sec, FFRT:0.8 sec max, 150 MCal/h | Yamatake | ![]() |